GPR and EM locating are complementary technologies for finding buried utilities. Here's how they compare and why we use both.
| Factor | Leak.ca | Electromagnetic Locators |
|---|---|---|
| Detects plastic pipes? | Yes — GPR sees density contrast | No — EM only detects metallic pipes/cables |
| Depth range | Up to 6m depending on frequency | Up to 6m depending on soil conductivity |
| Accuracy | 5-10cm horizontal, +/-10% depth | +/-5% depth in ideal conditions |
| Soil limitations | Reduced in wet clay | Reduced in high-EMI environments |
| Best for | Concrete scanning, rebar mapping, plastic pipes, voids | Live electrical lines, metallic pipes, telecom cables |